Number of elements: 2.
Insulation method: Phototriac.
Rated supply voltage: 12 to 24 VDC.
Applicable motor: 2.2 kW (11.1 A), 200 to 220 VAC.
Solid State Contactors That Can Drive 3-phase Motors Frequently,
and Achieve Harmonized Protection with Thermal.
Overload Relays.
Certified for UL and CSA V-164-1C26.
Mount with screws or to DIN tracks.
Compact monoblock construction (W: 80 × H: 100 × D: 100 mm)
V-164-1C26
with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.
Two-element models added to series. No. of poles: 4.
Connection method: Screw-on.
Suitable cable dia: 4 mm (4 to 5).
Core conductor size: 0 V-164-1C26. 18 to 0.75 mm.
Suitable sheath material: PVC, PE, PUR.
Straight Connectors .
Minimum order: 50.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors V-164-1C26.
A full line-up of models is planned .
Connectors with Cables are UL approved. Rated primary current: 5 A.
Rated secondary current: Special output.
Installation: Installed separately.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power .))
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor OMRON V-164-1C26.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settingss . OMRON V-164-1C26.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection.
V-164-1C26 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=V-164-1C26&select=5