C200H Accessory Programming Console Adapter C200H-BP001.Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms SGE-365-3-1000 00300M-00300F.
(Slow-action models with MBB contacts are available
SGE-365-3-1000 00300M-00300F)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads SGE-365-3-1000 00300M-00300F.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC . Item: Advanced models, External input models.
Functions: Remote setting, Counter, Differential operation.
Model: PNP output.
Variable Laser Beam for Spot, Line, or Area Detection.
Long-distance detection (diffuse reflective: 1 m, retro-reflective: 7 m) SGE-365-3-1000 00300M-00300F.
Beam shape selectable from spot, line, and area types to match various applications.
Adjustable spot diameter .
Adjustable optical axis.
The E3DC-LDA0, which supports the EtherCAT Sensor.
Communications Unit and the CompoNet Sensor.
Communications Unit, is also included in product lineup. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displayinng the status of the Temperature Controoller (auto/
manual, RUN/STOP, and alarms) and the PV or SV OMRON SGE-365-3-1000 00300M-00300F.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs OMRON SGE-365-3-1000 00300M-00300F.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
SGE-365-3-1000 00300M-00300F Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=SGE-365-3-1000 00300M-00300F&select=5