Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater SGE-365-2-1830 05000C.
Event entry point: 2.
Transfer output: transfer output (special terminal)
SGE-365-2-1830 05000C
Remote SP:4 to 20mA input.
Communication: RS-422.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance SGE-365-2-1830 05000C.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved .
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors SGE-365-2-1830 05000C.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV .
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Power supply voltage: 5 to 12 VDC.
Output configuration: Voltage outpu.
Resolution (pulses/rotation): 10, 20, 30, 40, 50, 60, 100, 200, 300,
360, 400, 500, 600; 720, 800, 1,000, 1,024, 1,200, 1,500, 1,800, 2,000.
General-purpose Encoder with.
External Diameter of 50 mm.
Incremental model.
External diameter of 50 mm.
Resolution of up to 2,000 ppr.
IP64 (improved oil-proof construction with sealed bearings).
Side or back connections are possible. Pre-wired Models with cable,
connected at an angle. Size: M12 (Brass); Single; Unshielded.
Sensing distance: 5 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Size: 48 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: RS-485.
Event input: 6 points.
Remote SP input: there.
Transfer output: have.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point traansfer output and remote SP inpuut, suitable for a wide range of applications OMRON SGE-365-2-1830 05000C.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperratture controller is connected to each other by using the component communication OMRON SGE-365-2-1830 05000C.
A new type of proportional control allows you to control the valve.
SGE-365-2-1830 05000C Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=SGE-365-2-1830 05000C&select=5