LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
SGE-225-5-0150 05000C-00100F OMRON SGE-225-5-0150 05000C-00100F
No PHOTO
OMRON SGE-225-5-0150 05000C-00100F
Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function OMRON SGE-225-5-0150 05000C-00100F.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422 SGE-225-5-0150 05000C-00100F
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure OMRON SGE-225-5-0150 05000C-00100F.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms .
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV OMRON SGE-225-5-0150 05000C-00100F.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output .
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (RJ45/RJ45).
Cable length: 0.3 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Measuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC.
Supply voltage: 100-115 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvolltages and,
undervoltages .
Mannual resetting and automatically resetting supported by one Relay SGE-225-5-0150 05000C-00100F.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input ssuppported SGE-225-5-0150 05000C-00100F.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
SGE-225-5-0150 05000C-00100F Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=SGE-225-5-0150 05000C-00100F&select=5


...more relevant model market price >>>>
Related products