Type: 1-Conduit.
Contact configuration: Slow-action MBB contact; 2NC/1NO.
Conduit opening/Connector: Pg13.5.
Multi-contact, Labor-saving,
Environment-friendly, Next,
generation Safety-door Switch.
Lineup includes three contact models with 2NC/1NO,
and 3NC contact forms and MBB models in addition,
to the previous contact forms 1NC/1NO, and 2NC OMRON S8JX-G15024.
M12-connector models are available, saving on,
labor and simplifying replacement
S8JX-G15024
Standardized gold-clad contacts provide high,
contact reliability.
Applicable to both standard loads and microloads.
Variety of metallic heads available. Output: DPDT.
Lighting: LED (with built-in reduced-voltage lighting function) OMRON S8JX-G15024.
Operating voltage: 100/110 VAC/VDC .
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads OMRON S8JX-G15024.
Easy-to-wire terminal arrangement .
Certified for EN 60947-5-1. Number of beams: 68.
Protective height: 1360mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Size: 48 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermoostat
(automaticc / manual, RUN/STOP, alarm), interactive display PV/SV S8JX-G15024.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation S8JX-G15024.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
S8JX-G15024 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=S8JX-G15024&select=5