OMRON XG8T-0231 XG8T-0231
No PHOTO
next one: OMRON XG8S-0431
Last one: OMRON XG8T-0631
OMRON XG8T-0231
Appearance: Square/Projection type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-C.
Output: SPST-NO.
Lighting: LED.
Operating voltage: 200 VAC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia OMRON XG8T-0231. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit XG8T-0231
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type OMRON XG8T-0231.
(round-type) crimp terminals .
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Number of beams: 40.
Protective height: 800mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A OMRON XG8T-0231.
Blanking can be set .
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is inddicated from the start of operation XG8T-0231.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions XG8T-0231. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
XG8T-0231 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=XG8T-0231&select=5