Type: CJ1 Special I/O Unit.
Name: CompoBus/S Master Unit.
Specifications: Communications functions,
Remote I/O communications; No. of I/O points,
256 max. (128 inputs and 128 outputs);
Max. Units mountable per CPU Unit: 40.
No. of unit numbers allocated: 1 or 2(variable).
Current consumption : 5V, 0 UMYM10-1000-0900 Price. 15A; 24V,--.
Standards: UC1, N, L, CE.
CompoBus/S is a high-speed I/O bus. I/O classification: Digital input
UMYM10-1000-0900
Internal I/O circuit common: NPN (+ common).
I/O points: 16.
I/O connection method: Sensor connector.
Compact Remote I/O Terminals that.
Save Wiring Effort and Enable.
Long-distance Communications UMYM10-1000-0900 Price.
Long-distance or high-speed communications,
mode is selectable.
Incorporates I/O connectors making it possible to,
minimize the size .
I/O connectors save wiring effort.
Flexible DIN track mounting is possible through a,
DIN track attachment.
Eight-point sensor connector models and 16-point,
MIL connector models are the same size. Name: Basic Unit (temperature control) *1 UMYM10-1000-0900 Price.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2 .
Control outputs 3 and 4: Transistor output: 2 points (sinking).
Auxiliary output: None.
Functions: burnout Heater alarm, 2 *3; Event inputs, 2 .
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Conneect directly to the G3ZA Muulti-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise OMRON UMYM10-1000-0900.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullatte the PID constants with the step,
response method OMRON UMYM10-1000-0900.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.
UMYM10-1000-0900 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=UMYM10-1000-0900&select=5