Optical system: diffuse type.
Detection distance: 1500 positive and negative 500mm.
Beam shape: linear beam.
Beam diameter: 40mm * 1.5 m.
Resolution: 500 m.
Cable length: 0.5m. Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0 OMRON . 100 A; 60 Hz, 0.090 A .
Rated input: 50 Hz, 15 W ; 60 Hz, 14 W .
Rated rotational speed: 50 Hz, 2450 r/min; 60 Hz, 2700 r/min
Y92E-E12
Maximum flow rate: 50 Hz, 2.2 m3/min; 60 Hz, 2.5 m3/min.
Maximum static pressure: 50 Hz, 63.7 Pa; 60 Hz, 63.7 Pa.
Noise: 50 Hz, 39 dB; 60 Hz, 42 dB.
Optimum Cooling with a Comprehensive OMRON .
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment .
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA OMRON .
Note: The compliant standards and certified safety standards depend on the,
product . Check the information given for available models of Axial fans and,
the information in Characteristics. Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Roller lever, high sensitivity.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Type: plug - in.
Size: 48 x 96mm.
Control output 1: linear current output.
Control output 2: relay output.
Auxiliary output: 2 points.
Communication: RS-485.
Heater disconnection: -.
Event input: 2 points.
Power supply voltage: AC100 ~ 240V.
Using large font PV display (white), improve visibility.
Selection, setting and operation more simple and more group of input / outpput,
Functional peerformance is stronger, the function is more perfect and more extensive range of applications OMRON Y92E-E12.
E5EC-800 white LCD-PV display height is about 18mm,
The E5AC-800 white LCD-PV display height is about 25mm improved visibility.
The maain body is short, the thickness is only 60mm OMRON Y92E-E12.
50ms high speed sampling period.
A new type of proportional control allows you to control the valve.
Y92E-E12 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=Y92E-E12&select=5