Size: M8, Non-shielded.
Sensing distance: 4.0 mm.
Connection: M12 connector.
Body material: Stainless steel.
Thread length (overall length): 49 (65).
Output configuration: PNP.
Operation mode NO.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor OMRON .
Problems such as the collision of workpieces are eliminated
SGE-245L-0-1680 05000C-05000C
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Appearance: L-shaped.
Sensing method: Through-beam type (with slot) OMRON .
Cable length: 2 m.
Sensing distance: 5 mm (slot width).
configuration Output: Light-ON .
Indicator mode: Incident light.
Model: PNP output.
Slim, Compact Photomicrosensor.
that is still easy to use.
Compact, thin profile enables dense mounting.
Indicator is visible from both sides.
Wide operating voltage range: 5 to 24 VDC. Size: 48 x 24mm.
Control output 1: voltage output (SSR driver) OMRON .
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC100 ~ 240V .
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately). Type: Welding / wire type, with right column.
Driving rod: R type swing lever type.
Terminal specifications: with wire, under the lead.
Contact specifications: 1a .
The minimmum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment OMRON SGE-245L-0-1680 05000C-05000C.
No swing bars are also used fforr easy long stroke specifications (OT reference value: 1 OMRON SGE-245L-0-1680 05000C-05000C. 4mm).
Without harmful substances to the environment, the lead type has also been lead-free.
SGE-245L-0-1680 05000C-05000C Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=SGE-245L-0-1680 05000C-05000C&select=5