LK Automation Limited LK Automation Limited
Information sort OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Supply
OMRON CP1E-N60S1DR-A CP1E CPU Units


Product name: Pulse I/O Module.
Specifications: Sourcing outputs, MIL connector,
10 inputs (including four interrupt/quickresponse,
inputs and two high-speed counter inputs)6 outputs,
(including two pulse outputs and two PWM outputs).
Current consumption (A): 5V, 0.08; 24V,-- CP1E-N60S1DR-A.
Standards: UC1, N, L,CE.
CJ2M for basic machine autoomation.
The CJ2M Series is ideal for packaging and general.
machine automation needs. Connectivity is assured.
thanks to the built-in USB port and the choice of CP1E-N60S1DR-A.
Ethernet and RS-232C/422/485 interfaces on the CPU.Power supply: DC power supply.
Output method: Transistor output source type.
Inputs points: 18 points OMRON CP1E-N60S1DR-A.
Outputs points: 12 points.Name: e-CON Connectors.
Specifications: Inputs/Outputs;
8 inputs /8 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection CP1E-N60S1DR-A.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet OMRON CP1E-N60S1DR-A.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON CP1E-N60S1DR-A.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100, Pt50, Ni508.4.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.07A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems CP1E-N60S1DR-A.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.

Related supply information