LK Automation Limited LK Automation Limited
Information sort OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Supply
FX1S-20MT-D PLC MITSUBISHI FX1S-20MT-D


Max input / output points: 16 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 8 points.
Output type: transistor.
Power consumption: 30VA.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x87.
Note recording function, Component annotation can be recorded in the program register FX1S-20MT-D.
Online program editoor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate FX1S-20MT-D.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard FX1S-20MT-D.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V MITSUBISHI FX1S-20MT-D.
Frequency converter capacity: 5.5KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible MITSUBISHI FX1S-20MT-D.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced MITSUBISHI FX1S-20MT-D.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft.
Max input / output points: 20 points.
Power supply voltage: DC24V.
Input points: 12 points.
Output points: 8 points.
Output type: Transistor (source).
Power consumption (W): 20.
Weight (kg):0.4.
Size (WxHxD) mm:75x90x75.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time.
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.<
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O FX1S-20MT-D.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication.

Related supply information