C500-ID I/O Unit DC Input 32 pts C500-ID218CN(3G2A5-ID218CN).
DC12-24V 10mA.Specification: Platinum resistance thermometer input (Pt, JPt),
ON/OFF or advanced PID control,
tran-sistor (PNP) output, 2 loops.
Unit classification: CJ1 CPU Bus Unit.
Product name: EtherNet/IP Unit CJ1W-EIP21.
Specifications:Communications cable,
Shielded twisted-pair SSTP),
cable Categories: 100 Ω at 5,5e;
Communications functions, Tag Data Link,
Functions, Message Communications Functions;
Units per CPU Unit, 8 max CJ1W-EIP21.
No. of unit numbers allocated: 1.
Current consumption: 5V system, 0.41A;
24V system, --.
Standards: UC1, N, L, CE.
Introducing the New EtherNet/IP Unit.
More Than 180,000 Words of Tag,
Data Link Capacity!
EtherNet/IP is an industrial multivendor,
network that uses Ethernet CJ1W-EIP21.
Managed by the ODVA (Open DeviceNet Vendors,
Association), it has open standards and is,
used with a wide range of industrial devices.
The EtherNet/IP Unit supports tag data links,
to enable sharing data between devices at,
Ethernet nodes and a message service for,
sending and receiving data when required OMRON CJ1W-EIP21.
The EtherNet/IP Unit supports the same,
FINS/UDP and FINS/TCP functionality,
as Ethernet Units.
Unit type: CS1 Special I/O Units.
Product name: Isolated-type Resistance,
Thermometer Input Units (Ni508 OMRON CJ1W-EIP21.4 Ω).
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: INi508.4.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block OMRON CJ1W-EIP21.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems CJ1W-EIP21.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.