C200H A Backplane I/O Mounting Bracket For 8 Slots C200H-ATTA3.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100 CJ1W-MAD42.
Conversion speed (resolution):
250 ms/8 inputs.
Externaa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE CJ1W-MAD42.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value CJ1W-MAD42.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them OMRON CJ1W-MAD42.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available OMRON CJ1W-MAD42.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools OMRON CJ1W-MAD42.
Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 inputs ; 2 outputs.
Signal range selection:
Set separately for each input and output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA.
Resolution: 1/4,000 (Settable to 1/8,000).
Conversion period: 1 ms/point,
(Settable to 500 μs/point).
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.2% of F.S;
Voltage: ±0.3% of F.S. Current: ±0.3% of F.S.
External connection: Removable terminal block.
External power supply: 24 VDC +10% -15%, 140mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.58A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Miicrosecond Throughput:
Models with Direct Conversion Join the Lineup CJ1W-MAD42.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals.