A1SJ71B62-S3 Modular And then combine the data and the program with CPU MITSUBISHI A1SJ71B62-S3


Input type: DC input, positive / negative public end.
Input points: 8 points.
Enter the response time: 0.2ms below, below 1.5ms, 5ms below, 10ms the following.
Rated input voltage / current: DC12V/7mA.
Output form: relay output.
Output points: 8 points.
OFF leakage current: - A1SJ71B62-S3.
Output protection function: No.
Rated load volltage / current: DC24V/AC240V/0.5A.
External connection: 3 line /2 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup A1SJ71B62-S3.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A1SJ71B62-S3. Adapter for mounting rails. I/O unit.
Signal transmission device B/NET interface device for power distribution control equipment
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on MITSUBISHI A1SJ71B62-S3.
This phenomenon is called the I/O delay time effect MITSUBISHI A1SJ71B62-S3.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CPU.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive MITSUBISHI A1SJ71B62-S3. A6WU-A6PHP/A6HGP connection cable.
Length: 0.3m. Peripheral equipment A/QnA series CPU unit connection cable.Close to input / output: 8 DC input or keyboard: 64 DC input, 16 transistor output.
Applicable model: A985/975/970/A960GOT (-B). The most appropriate temperature regulation control (PID control) is possible,
In order to control the PID does not need to specify a special command.
In addition, according to the automatic regulation function,
The automatic setting of PID number is possible.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
> The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on A1SJ71B62-S3.
This phenomenon is called the I/O delay time effect.