Cable with connector (1 to 2) /G79-I_-_-D1,
G79-O_-_-D1, G79-M_-_-D1.
Size: A, 750mm; B, 500mm.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow) G3S4-D PDF datasheet .
Applicable output load (See note 1.): 20 A at 200 to 480 VAC.
Rated input voltage: 5 to 24 VDC
G3S4-D
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges G3S4-D PDF datasheet .
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Mounting type: W-bracket(see note).
Contact form: DPST-NO/DPST-NC.
Screw terminals.
A High-capacity, High-dielectric-strength,
Multi-pole Relay Used Like a Contactor G3S4-D PDF datasheet .
Miniature hinge for maximum switching power for motor loads,
as well as resistive and inductive loads.
No contact chattering for momentary voltage drops up to 50%,
of rated voltage.
Withstanding more than 4 kV between contacts that are differ,
ent in polarity and between the coil and contacts OMRON G3S4-D PDF catalog.
Flame-resistant materials (UL94V-0-qualifying) used for all in,
sulation material OMRON G3S4-D PDF catalog.
Standard models approved by UL and CSA.
Isolation: Phototriac coupler.
Zero cross function: NO.
Indicator: NO.
Rated output load: 3 A at 100 to 240 VAC (See note 1.).
Rated input voltage: 5 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays OMRON G3S4-D PDF catalog.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”).
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes.
Applicable output load(See note 2 G3S4-D datasheet. ): 5 A at 24 to 220 VAC (at 40°C).
Rated input voltage: 5 to 24 VDC.
SSR with output (5 to 90 A) at a reasonable price
Zero cross function enables less noise operation.
Built-in varistor efffectively absorbs external surges G3S4-D PDF datasheet .
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Certified by UL, CSA and TÜV.