Temperature control module AJ65BT-68RD3 datasheet PDF catalog MITSUBISHI AJ65BT-68RD3 PDF datasheet
Product model: AJ65BT-68RD3
Name: Temperature control module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 16A/1 public end.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
8 point /1 a public side.
20 point terminal station.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor AJ65BT-68RD3 PDF catalog AJ65BT-68RD3
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc AJ65BT-68RD3 PDF catalog . .
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process AJ65BT-68RD3 PDF catalog MITSUBISHI AJ65BT-68RD3 PDF datasheet.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MITSUBISHI AJ65BT-68RD3 PDF datasheet MITSUBISHI AJ65BT-68RD3 PDF datasheet. 8 channel annalog input module AJ65BT-68RD3 datasheet.
This is a high density of 8 channel A/D components,
Can receive voltage and current input, with the installation of the inside of the cover plate switch,
The input type and range of each channel can be sset up according to the application requirements:
12 bit resolution,
Automatic drift correction function,
0 AJ65BT-68RD3 PDF catalog . 5msec/1 channel,
-10-0-10V or 0-20mA input.
Related products
MITSUBISHI
DC input module
AJ65BTB1-16D
MITSUBISHI DC input module AJ65BTB1-16D
Input type: DC input, positive pulic en
MITSUBISHI
CC-Link connection unit
AJ65BT-G4-S3
MITSUBISHI CC-Link connection unit AJ65BT-G4-S3
CC-Link peripheral device connection. RS
MITSUBISHI
Temperature control module
AJ65BT-68RD4
MITSUBISHI Temperature control module AJ65BT-68RD4
Screw, 2 piece type terminal Platinum te
MITSUBISHI
High speed counting module
AJ65BT-D62D
MITSUBISHI High speed counting module AJ65BT-D62D
Pulse input: differential input. Default