Manual pulse generator /INC synchronous encoder input:
Use number: 3 sets of /1 modules.
Automatically transfer the record file to the FTP server
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to the FTP server.
Because the record server can handle multiple files, it can reduce the task of management and maintenance MITSUBISHI QD75P4N PDF datasheet
QD75P4N
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do not have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution.Input: 4 channels.
Thermocouple (C1602-1995 JIS) MITSUBISHI QD75P4N PDF datasheet.
Conversion speed: 40ms/1 channel.
18 point terminal station.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance.
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery MITSUBISHI QD75P4N PDF datasheet.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion.
The next time the power is turned on, the backup data will be automatically restored.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown. 8 channel.
Input: DC4~20mA.
Output (resolution): 0~6400; 0~3200.
Conversion speed: 10ms/ channel.
18 point terminal station.
Isolation between channels.
Power supply to a two wire transmitter.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier QD75P4N PDF catalog.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input modulee QD75P4N PDF catalog.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.