Q00JCPU-S8 PDF datasheet MITSUBISHI Q00JCPU-S8 datasheet PDF catalog
Product model: Q00JCPU-S8
Name: CPU with base plate
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Three-phase 3 wire type.
Measuring circuit number: 1 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc..
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information MITSUBISHI Q00JCPU-S8 PDF catalog Q00JCPU-S8
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment MITSUBISHI Q00JCPU-S8 PDF catalog.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products.
For example, a module can be used to measure other loads from the control panel trunk MITSUBISHI Q00JCPU-S8 PDF catalog.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.MODBUS/TCP Master slave station.
10BASE-T/100BASE-TX.
MODBUS interface module capable of connecting MODBUS compatible device such as temperature regulator, measuring device and so on.
Support MODBUS communication function, and can be compatible with the third party MODBUS to communicate from various station equipment.
Support MODBUS communication functions from the station, can communicate with the third party programmable controller MODBUS master device.
Through the linkage function, the master can be connected to the CH1 side (RS-232),
And through the QJ71MB91 and connected to the CH2 side (RS-422/485) of a number of stations for communication.
The RS-232 interface (11 credit on the 1 pass) MODBUS master device with multiple MODBUS communication from the station equipment Q00JCPU-S8 PDF datasheet. (only QJ71MB91)
Master / slave station functions can be used simultaneously. (only QJ71MT91)Battery replacement.
Iniitial voltage 3 Q00JCPU-S8 PDF datasheet. 0V.
Replace large capacity battery module with cable.
Current capacity: 18000mAh.
Service life: 5 years.
Outline dimension: 98*55.2*87mm