Release key type: Special release key.
Indicator: Green.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+2NC/1NO.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns D4N-2A20R PDF catalog .
Standard gold-clad contacts enable use with ordinary loads,
and microloads
D4N-2A20R
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Actuator: Plunger.
Conduit size: 2-conduit; M20 D4N-2A20R PDF catalog .
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement D4N-2A20R PDF catalog .
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Plunger OMRON D4N-2A20R PDF datasheet.
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available OMRON D4N-2A20R PDF datasheet.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads OMRON D4N-2A20R PDF datasheet.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Type of drive rod: plunger type.
Conduit size: single catheter type, M20.
Built in switch structure: slow motiion (1NC) D4N-2A20R datasheet.
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forcedd open action structure D4N-2A20R PDF catalog .
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.