Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: - E2EH-X12D2 2M PDF datasheet .
Event input points: -.
Transfer output: -.
Communication: -
E2EH-X12D2 2M
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm) E2EH-X12D2 2M PDF datasheet .
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultSize: 1/16 DIN 48 × 48 × 78 (W × H × D) E2EH-X12D2 2M PDF datasheet .
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or Resistance thermometer OMRON E2EH-X12D2 2M PDF catalog.
Alarm output: 2.
option units Mounting: Yes.
Control output: Current output.
Previous mode: E5CZ-C2MD.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better OMRON E2EH-X12D2 2M PDF catalog.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm) OMRON E2EH-X12D2 2M PDF catalog.
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled.
Manual output provided.
New protocol called Modbus is installed in the models,
with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output 1: voltage output (SSR driveer) E2EH-X12D2 2M datasheet.
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power suppply: single phase heater with detection function E2EH-X12D2 2M PDF datasheet .
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded