Size: M8, Non-shielded.
Sensing distance: 4.0 mm.
Connection: Pre-wired.
Body material: Stainless steel.
Thread length (overall length): 27 (40).
Output configuration: NPN.
Operation mode NO.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor E5CN-HTV2BF PDF catalog .
Problems such as the collision of workpieces are eliminated
E5CN-HTV2BF
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Sensing method: Through-beam.
Connection method: Pre-wired (2 m).
Sensing distance: 300 mm.
Operation mode: Light-ON.
Model: NPN output.
Makes Mounting and Installation Simpler and Smoother E5CN-HTV2BF PDF catalog .
Suitable for Applications in the Rechargeable Battery Industry. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Auxiliary outputs: 1.
Control output 1: Voltage output (for driving SSR).
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance E5CN-HTV2BF PDF catalog . Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0 OMRON E5CN-HTV2BF PDF datasheet. 5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV OMRON E5CN-HTV2BF PDF datasheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter. Size: 96 x 96mm.
Ontology: terminal type, analog input type OMRON E5CN-HTV2BF PDF datasheet.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 4.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuall, RUN/STOP, alarm), interactive display PV/SV E5CN-HTV2BF datasheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CN-HTV2BF PDF catalog .
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.