Name: Clamp Terminal Blocks.
Specifications: Inputs; 8 inputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction CS1W-OC201 PDF catalog .
Seven-segment Display on the Gateway Unit,
helps to detect errors on site
CS1W-OC201
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 outputs;
Signal range selection:
Set separately for each output CS1W-OC201 PDF catalog .
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA; 1/4,00.
Conversion period: 1 ms/point.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.3% of F.S. Current: ±0.5% of F.S.
External connection: Removable terminal block.
External power supply: 24 VDC +10% -15%, 200mA max.
No. of unit numbers allocated: 1 CS1W-OC201 PDF catalog .
Current consumption: 5V, 0.12A; 24V, 0.2*3.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data OMRON CS1W-OC201 PDF datasheet.
Analog Output Units for converting binary ,
data into analog output signals.
Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units OMRON CS1W-OC201 PDF datasheet.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0 OMRON CS1W-OC201 PDF datasheet. 15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space coompared,
with previous systems CS1W-OC201 datasheet.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-OC201 PDF catalog .
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.