Category: incidental cover type.
Structure: DIN guide rail mounting type.
Capacity: 150W.
Output voltage: 24V.
Output current: 6.5A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function S8AS-24006 PDF datasheet.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity
S8AS-24006
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock S8AS-24006 PDF datasheet.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
I/O classification: Input and output S8AS-24006 PDF datasheet.
Internal I/O circuit common: PNP (input: – common; output: + common).
I/O points: 32.
I/O connection method: MIL connector.
Rated voltage for communications power supply: 24 VDC.
Rated voltage for I/O power supply: 24 VDC.
Applicable relay: G3DZ-2R6PL.
Subminiature 32-point Remote Terminal with Connectors.
Compact dimensions: 35 × 60 × 80 (W × D × H).
Long-distance and high-speed communications modes available.
Downsizing enabled with 32-point MIL connector for I/O connection.
Easy-to-use DIN Rail Mounting Bracket for,
Power Supplies.
Mounts to the PFP-100N and PFP-100N2 DIN Rails.
Supports models S82J (100, 150-W models). Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*1).
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standdards S8AS-24006 PDF catalog.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) S8AS-24006 PDF catalog.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)