OMRON K3HB-XAD-FLK3AT11 AC/DC24 PDF datasheet K3HB-XAD-FLK3AT11 AC/DC24 datasheet PDF catalog
Product model: K3HB-XAD-FLK3AT11 AC/DC24
Name: Voltage and current panel meter
Brand: OMRON
Sort: PDF datasheet
File language: English
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function K3HB-XAD-FLK3AT11 AC/DC24 PDF datasheet.
Simple temperature measurements with Temperature Sensor included in the Unit K3HB-XAD-FLK3AT11 AC/DC24
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power K3HB-XAD-FLK3AT11 AC/DC24 PDF datasheet.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage K3HB-XAD-FLK3AT11 AC/DC24 PDF datasheet.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Static voltage relay.
K2VR-S/K2VA-S type, high action reliability disk with static type UVR/OVR.
Accurate work through high reliability semiconductor circuits.
Type K2VU-S1 is the output contact, but will be closed when the voltage is not enough,
Therefore, the locking time sequence circuit of the circuit breaker is not required.
Within the hidden from the start to the 2S timer, can easily adjust the time.
The control power of the relay is not needed, which avoids the trouble of wiring.
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cyccle of the digital time interval table K3HB-XAD-FLK3AT11 AC/DC24 PDF catalog.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displayingg the pulse interval between 2 points K3HB-XAD-FLK3AT11 AC/DC24 PDF catalog.
Pulse interval measurement range, the maximum measurable range from 10ms to 3200s.
6 kinds of measuring methods
Related products
OMRON
Temperature panel
K3HB-HTA-FLK1AT11 AC/DC24
OMRON Temperature panel K3HB-HTA-FLK1AT11 AC/DC24
Type of input: platinum resistance / the
OMRON
Time interval table
K3HB-PNB-FLK1AT11 AC/DC24V
OMRON Time interval table K3HB-PNB-FLK1AT11 AC/DC24V
Input type: NPN/ voltage pulse input typ