LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Catalog Download >> K2CU-F20A-DGS
OMRON K2CU-F20A-DGS PDF catalog K2CU-F20A-DGS datasheet PDF datasheet
Product model: K2CU-F20A-DGS
Name: Heater Element Burnout Detector
Brand: OMRON
Sort: PDF datasheet
File language: English
Product: Straight Bar Nozzle; 300 mm.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual K2CU-F20A-DGS PDF datasheet.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase) K2CU-F20A-DGS
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K2CU-F20A-DGS PDF datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM K2CU-F20A-DGS PDF datasheet. Function: Temperature monitoring.
Power supply voltage: 100 to 240 VAC.
Monitor Temperature Rise through.
Internal Motor Loss.
Temperature, phase sequence, and phase loss monitoring with,
the DIN 22.5-mm-sized K8AK-PT Relays.
Side-by-side mounting of K8AK-PT Relays.
Specially designed for internal motor monitoring; no setting required.
Test/Reset Button for confirmation of output operation.
Monitoring also performed for thermistor disconnections and short circuits.
Manual or automatic resetting with the same Relay. Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K2CU-F20A-DGS PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2CU-F20A-DGS PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Heater Element Burnout Detector
K2CU-F80A-D
OMRON Heater Element Burnout Detector K2CU-F80A-D
Control supply voltage: 110 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-F80A-F
OMRON Heater Element Burnout Detector K2CU-F80A-F
Control supply voltage: 220 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-F10A-EGS
OMRON Heater Element Burnout Detector K2CU-F10A-EGS
Control supply voltage: 200 VAC With vo
OMRON
Heater Element Burnout Detector
K2CU-F40A-EGS
OMRON Heater Element Burnout Detector K2CU-F40A-EGS
Control supply voltage: 200 VAC With vo