LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Catalog Download >> K2CM-Q1M
OMRON K2CM-Q1M PDF datasheet K2CM-Q1M datasheet PDF catalog
Product model: K2CM-Q1M
Name: Motor Protective Relay
Brand: OMRON
Sort: PDF datasheet
File language: English
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay contact: H; PASS1c, L, each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V K2CM-Q1M PDF datasheet.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K2CM-Q1M
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum can be measured from 10ms to 320Power supply voltage: 100 to 240 VAC K2CM-Q1M PDF datasheet.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload K2CM-Q1M PDF datasheet.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Rated input (See note 2.): 3-phase 3-wire mode, 3-phase 4-wire mode;
380, 400, 415, 480 VAC, 220, 230, 240, 277 VAC.
Ideal for monitoring 3-phase power supplies.
for industrial facilities and equipment.
Monitor overvoltages and undervoltages for tthree-phase 3-wire,
or 4-wire power supplies K2CM-Q1M PDF catalog.
DIP switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Separate outputs possible for overvoltages and undeervoltages K2CM-Q1M PDF catalog.
World-wide power specifications supported by one Unit,
(switchable using DIP switch).
Relay status can be monitored using LED indicator.
Related products
OMRON
Motor Protective Relay
K2CM-2LS
OMRON Motor Protective Relay K2CM-2LS
Time specification: Inverse type. Curren
OMRON
Motor Protective Relay
K2CM-1HA
OMRON Motor Protective Relay K2CM-1HA
Time specification: Inverse type. Curren
OMRON
Motor Protective Relay
K2CM-Q2M
OMRON Motor Protective Relay K2CM-Q2M
Time specification: Instantaneous type.
OMRON
Motor Protective Relay
K2CM-Q1HA
OMRON Motor Protective Relay K2CM-Q1HA
Time specification: Instantaneous type.