DIN 48 X 48-mm Power OFF-delay Timer.
Long power OFF-delay times;
S-series: up to 12 seconds,
M-series: up to 12 minutes.
Models with forced-reset input are available.
11-pin and 8-pin models are available. Large Setting Dial and Moving Pointers Ideal,
for Easy Operation and Monitoring.
Incorporating an easy-to-see large setting dial with moving pointers H5CX-A11S-N PDF datasheet.
Wide time-setting range of 0
H5CX-A11S-N2 s to 60 h.
(available through three time-range model types).
Wide AC power supply range (100 to 240 VAC).
IP65 watertight and dust-tight front panel.
Approved by UL and CSA.
Conforms to EN61812-1 and IEC60664-1.
4 kV for Low Voltage, and EMC Directives.
Conforms to EMC standards.
Six-language instruction manual provided H5CX-A11S-N PDF datasheet.
Programmable contact enables the building of a self-holding,
relay circuit as well as built-in instantaneous contact. (-NS).
Memory retention (-NSR).
Finger protection terminal block.
Enables easy sequence checks through instantaneous outputs.
for a zero set value at any time range. Type: H5CZ.
Time specifications: Timer Mode, A-2: Power ON Delay I,
b: Repeat cycle 1, E: Interval, Z: ON/OFF-duty-adjustable flicker,
Twin Timer Mode, toff: Flicker OFF Start 1, ton: Flicker ON Start 1 H5CX-A11S-N PDF datasheet.
Operating modes: Timer Mode A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2.
External connections: 8-pin socket.
Inputs: None.
Outputs: Contact output (time-limit SPDT + instantaneous SPDT) Models with, instantaneous contact outputs.
Supply voltage: 100 to 240 VAC.
Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability.
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reliability.
Power supply circuit and input circcuits are isolated for safety and reliability H5CX-A11S-N PDF catalog.
Set value limit function prevents unexpected operation of output devices.
caused by setting mistakes.
Output counter function helps in managing the service life of the Timer oor,
the load H5CX-A11S-N PDF catalog.
Other Features.
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection.