Category: relay output.
Points: 8 points (1a * 8).
Common line processing on the connector side: NPN correspondence (+ public).
Rated voltage: DC24V.
Achieve control cabinet miniaturization / save time,
Relay terminal for 8 point output.
Small size of 68 * high 80 * 44mm. (vertical installation)
Total wiring of connector cable G70A-ZOC16 Series datasheet.
The common end can be easily connected with the independent contact and the short circuit piece
G70A-ZOC16 Series
The G70D-SOC08 and G70R-SOC08 are connected by a short circuit chip.
When the relay does not need the tool, the relay is convenient to replace the work.
With terminal cover to prevent electric shock.
With action indication LED.
Diode for internal coil surge absorption.
DIN guide rail installation, screw mounting common G70A-ZOC16 Series datasheet. Terminal (Wire connection): Screw terminal.
Classification: Standard.
Latching lever (Test switch): No.
Rated input voltage: AC/DC, 48V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape G70A-ZOC16 Series datasheet.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Input capacity: 32 points.
Internal I/O common: PNP.
ON voltage: 15 VDC min. (between each in,
put terminal and the G terminal).
OFF voltage: 5 VDC max. (between each in,
put terminal and the G terminal).
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms,
1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms.
(Default setting: 1ms)
Number of circuits per common: 32 points/common.
Input indicators: LED display (yellow).
Isolation method: No isolation.
I/O power supply method: Supplied from unit power supply.
Input device supply current: 50 mA/point.
Unit power supply current consumption: 230 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 220 g max.
Expansion functions: No.
Short-circuit protection function: Available.
(Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector G70A-ZOC16 Series PDF datasheet.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
sswitch and with tool software G70A-ZOC16 Series PDF datasheet.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.