Terminal (Wire connection): Push-In Plus Terminal.
Classification: Standard.
Latching lever (Test switch): No.
Rated input voltage: DC, 12V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel G3RV-SR500-A DC24 PDF datasheet.
Realized opening and closing ability with one pole 6 A slim shape
G3RV-SR500-A DC24
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs G3RV-SR500-A DC24 PDF datasheet.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Classification: Equipped with operation indicator and diode to absorb coil surge.
Contact form: 4PST (standard).
Mounting method: DIN Track or screw mounting.
Terminals: Phillips screw terminal.
Rated voltage: 5 VDC, 12 VDC, 24 VDC.
Compact Terminal Relay with 4 Independent G3RV-SR500-A DC24 PDF datasheet.
Outputs.
Equipped with four G6B Mini-relays that are compact, highly sen,
sitive, and highly resistant to dielectric surges, and that can switch,
5 amps of power.
Sealed plastic construction used for relays.
Easy wiring with separated input/output terminals.
Special P6B Mounting Socket used to facilitate maintenance,
(except for high-reliability models).
UL and CSA certification for standard models,
(except for high-reliability models).
VDE certification for G6B-4BND/47BND/48BND for 12/24 VDC.
DIN Track mounting, and screw mounting models are available. Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 24 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators G3RV-SR500-A DC24 PDF catalog. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in teemperature fuse prevents internal burning due to,
triac or relay malfunctions G3RV-SR500-A DC24 PDF catalog.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays.