Number of elements: 3.
Insulation method: Phototriac.
Rated supply voltage: 12 to 24 VDC.
Applicable motor: 2.2 kW (11.1 A), 200 to 220 VAC.
Solid State Contactors That Can Drive 3-phase Motors Frequently,
and Achieve Harmonized Protection with Thermal.
Overload Relays.
Certified for UL and CSA G3J-205BL-2 DC12-24 datasheet.
Mount with screws or to DIN tracks.
Compact monoblock construction (W: 80 × H: 100 × D: 100 mm)
G3J-205BL-2 DC12-24
with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.
Two-element models added to series. Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: No.
Applicable load: 25 A, 100 to 240 VAC G3J-205BL-2 DC12-24 datasheet.
Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents. (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification) G3J-205BL-2 DC12-24 datasheet. Cable and loose wire cable with loose wire connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Isolation: Photo-voltage coupler.
Zero cross function: No.
Indicator: Yes.
Rated output load: 0.5 A at 24 to 240 VAC, 0.5 A at 24 to 110 VDC.
Rated input voltage: 24 VDC.
100-A-max. Leakage Current, No Bleeder.
Resistor Required.
1 mA to 500 mA micro-load switching.
Switch to both AC and DC with no polarity.
Switch for a wide range of voltages; 19.2 to 264 VAC, 19.2 to 125 VDC.
Switch full- and half-wave rectifier AC loads.
Same sizes and terminal arrangements as OMRON Power,
Relay MY Series.
Operating indicator provided.
Switch MY Series (without bleeder resistor).
Superior surge absorption with a built-in varistor.
Optimum SSR to control minute load, valves, and solenoids. Insulation method: Phototriac.
Operation indicator: Yes.
Zero cross function: Yes.
Applicable load: 2 A at 100 to 240 VAC G3J-205BL-2 DC12-24 PDF datasheet.
Input rated voltage: 5 to 24 VDC.
SSR with Plug-in Terminals.
The Same Shape as the G2R-1-S.
Power Relays.
These I/O solid state relays can be mounted in OMRON.
G70A I/O Terminals.
Lineup includes Input Modules for microloads and Output,
Modules for standard loads G3J-205BL-2 DC12-24 PDF datasheet.
Lineup also includes UL, CSA, and TÜV-certified models,
(-UTU models).