Cable with connector (1 to 1) /G79-I_C, G79-O_C.
L size: 250mm.
Input use
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler G3F-202SN-VD AC100/110 PDF datasheet.
Zero cross function: Yes.
Operation indicator: Yes
G3F-202SN-VD AC100/110
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 35 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters G3F-202SN-VD AC100/110 PDF datasheet.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV) G3F-202SN-VD AC100/110 PDF datasheet.
The G3PF-2@@B-@@@ Series is UL certified. Terminal (Wire connection): Screw terminal.
Classification: Standard.
Latching lever (Test switch): No.
Rated input voltage: AC/DC, 24V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Isolation: Photo-voltage coupler.
Zero cross function: No.
Indicator: Yes.
Rated output load: 0.5 A at 24 to 240 VAC, 0.5 A at 24 to 110 VDC.
Rated input voltage: 12 VDC.
100-A-max. Leakage Current, No Bleeder.
Resistor Required.
1 mA to 500 mA micro-load switching.
Switch to both AC and DC with no polarity.
Switch for a widee range of voltages; 19 G3F-202SN-VD AC100/110 PDF catalog. 2 to 264 VAC, 19.2 to 125 VDC.
Switch full- and half-wave rectifier AC loads.
Same sizes and terminal arrangements as OMRON Power,
Relay MY Series.
Operating indicator provided.
Switch MY Series (without bleeder resistor) G3F-202SN-VD AC100/110 PDF catalog.
Superior surge absorption with a built-in varistor.
Optimum SSR to control minute load, valves, and solenoids.