Appearance: Shielded, M30.
Sensing distance: 15 mm.
Output configuration: DC 2-wire (without polarity) (3)-(4) pin arrangement.
Operation mode: NO.
Spatter-resistant Fluororesin,
coated Proximity Sensor.
Superior spatter resistance.
Long Sensing-distance Models added for sensing,
distances up to 15 mm E5EC-TRX4ASM-060 PDF catalog.
Pre-wired Smartclick Connector Models are also available. Size: M12 (Brass); Double; Unshielded
E5EC-TRX4ASM-060
Sensing distance: 16 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Size: 48 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V) E5EC-TRX4ASM-060 PDF catalog.
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 4.
Transfer output: output (special terminal).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / E5EC-TRX4ASM-060 PDF catalog.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV OMRON Digital temperature controller program PDF catalog.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay OMRON Digital temperature controller program PDF catalog.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Size: 48 x 96mm.
Control output 1: voltage output (SSR driver) OMRON Digital temperature controller program PDF catalog.
Control output 2:--.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP iinput, suitable for a wide range of applications E5EC-TRX4ASM-060 PDF datasheet.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperrature controller is connected to each other by using the component communication E5EC-TRX4ASM-060 PDF catalog.
A new type of proportional control allows you to control the valve.