LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Catalog Download >> E3Z-G62-S0SHW-E5
OMRON E3Z-G62-S0SHW-E5 datasheet PDF datasheet
Product model: E3Z-G62-S0SHW-E5
Name: Amplifier built-in type concave type photoelectric switch
Brand: OMRON
Sort: PDF datasheet
File language: English
Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Auxiliary outputs: 2.
Control output 1: Current output.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function E3Z-G62-S0SHW-E5 datasheet.
Indication Accuracy.
Thermocouple input: ±0 E3Z-G62-S0SHW-E53% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E3Z-G62-S0SHW-E5 datasheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive.
Lead wire length M : 8m.
A Wide Variety of High-precision E3Z-G62-S0SHW-E5 datasheet.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperaturre Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E3Z-G62-S0SHW-E5 PDF datasheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E3Z-G62-S0SHW-E5 PDF datasheet.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.