Power supply voltage: 12 to 24 VDC.
Output configuration: PNP open collector.
Output code: Gray code.
Resolution (divisions): 256, 360, 720, 1,024.
Connection method: Pre-wired Model.
Rugged Rotary Encoder.
Absolute model.
External diameter of 60 mm.
Resolution of up to 1,024 (10-bit).
IP65 oil-proof protection E3S-GS1E4 PDF datasheet.
Strong shaft.
Radial: 120 N, Thrust: 50 N. Type: controller with terminal blocks
E3S-GS1E4
Size: 1/4DIN, 96 * 96 * 78mm.
Power supply voltage: AC100 ~ 240V.
Type of input: thermocouple or platinum resistance.
Alarm output: 3.
Control output: current output.
Heater disconnection: yes.
Install optional unit: have.
Best selling multi purpose thermostat is now more outstanding.
Temperature controller is now available for analog input E3S-GS1E4 PDF datasheet.
A more rapid sampling rate 250ms.
Provide transfer output, can be simple output to the recorder.
The model is optional with the circuit breaking alarm (LBA) and the heater short circuit alarm (HS).
Simply set the 11 segment display.
Equipped with a manual output function.
New type of installation with communication Modbus.
USB serial conversion cable optional E3S-GS1E4 PDF datasheet. Item: Advanced models; External-input models.
Functions: Remote setting, counter, differential operation.
Model: PNP output.
Advanced Fiber Amplifier Units.
Features a Power Tuning function that optimizes light,
reception at the press of a button.
APC circuits to suppress LED aging degradation used with,
4-element LEDs.
2-channel models achieve the thinnest* profile in the industry,
at only 5 mm per channel.
2-channel models also offer AND/OR control output.
The E3X-MDA0 with two channels supports an EtherCAT Sensor.
Communications Unit or CompoNet Sensor Communications Unit. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Auxiliary outputs: 2.
Control output 1: Voltage output (for driving SSR).
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0. E3S-GS1E4 PDF catalog. 5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
mannual, RUN/STOP, and alarms) and the PV or SV E3S-GS1E4 PDF catalog.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.