Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: RS-485 E2E2-X10C2 PDF catalog.
Previous model: Thermocouple input, --;
Resistance thermometer input, --
E2E2-X10C2
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0 E2E2-X10C2 PDF catalog. 5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter E2E2-X10C2 PDF catalog.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Classification: General purpose Models.
Description: Sheathed platinum resistance thermometer.
Temperature range (See note 3 OMRON Long-barrel Inductive Proximity Sensor PDF catalog. ): -196°C to 450°C.
Element type: Pt100.
Conductor type: 3-conductor system.
Class: B OMRON Long-barrel Inductive Proximity Sensor PDF catalog.
Protective tubing material: SUS316.
Terminal type: Exposed lead wires.
Page: 5.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers OMRON Long-barrel Inductive Proximity Sensor PDF catalog.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Sensing method: Reflective type.
Sensing distance: 0 to 3 mm.
Output configuration: Turns ON when wafer carrier is present.
Cable length: 2 m.
Photomiicrosensors for detecting,
wafer-carrier mounting E2E2-X10C2 PDF datasheet.
The mounting position is set with a pedestal.
The contact surface with the wafer carrier uses a special chemical,
resistant fluororesin.
The unique optical system enabless stable detection of almost all,
wafer-carriers E2E2-X10C2 PDF catalog.
Light modulation effectively reduces external light interference.
Utilizes talc-free clean cables.