Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points E2E-CR8C2 2M PDF datasheet.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use
E2E-CR8C2 2M
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E2E-CR8C2 2M PDF datasheet.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation E2E-CR8C2 2M PDF datasheet.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Size: 1/16 DIN 48 × 48 × 78 (W × H × D).
Power supply voltage: 24 VAC/VDC.
Input type: Analog(current/voltage).
Alarm output: 2.
option units Mounting: Yes.
Control output: Current output.
Previous mode: None.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled.
Manual output provided.
New protocol called Modbus is installed in the models,
with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Terminal type: Exposed-lead Models.
Protective tubing diameter D: 6.4 dia.
Protective tubing length L: 50cm.
Lead wire type: Standard.
Lead wire length M: 1m.
A Wide Variety of High-precision.
Temperature Seensors E2E-CR8C2 2M PDF catalog.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E2E-CR8C2 2M PDF catalog.