Free change detection direction.
Detection direction can be according to the front, side (up and down, around 90 units) change.
Can be similar to the feeling of a limit switch installation.
Type: DC type.
Shape: non shield.
Detection range: 30mm.
Output form: NO PNP + NC (dual output). Appearance: M5 E2B-S08LN04-MC-C2 PDF catalog.
Sensing distance: 1.2 mm.
Connecting method: M8 Pre-wired Connector Models
E2B-S08LN04-MC-C2
Cable specifications: --.
Operation mode: NC.
Wire color /pin arrangement: 1: +V, 3: 0 V, 4: Control output.
Model: NPN output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5.4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available E2B-S08LN04-MC-C2 PDF catalog.
High-speed response frequency stably detects moving,
objects: 5 kHz max.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only).
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables E2B-S08LN04-MC-C2 PDF catalog. Size: Shielded, M12.
Sensing distance: 2 mm.
Output: Polarity Pin allocations: 1-4.
Operation mode: NO.
Highly Durable Proximity Sensor for.
Tough Environments.
Completely stainless-steel housing.
Aluminum chip immunity OMRON Proximity Sensors PDF catalog.
Embedding installation to metal (steel) fittings.
Chemical resistance certified by Ecolab Europe.
Lineup includes pre-wire models and DC 3-wire NPN output,
models with fluororesin coating OMRON Proximity Sensors PDF catalog. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points OMRON Proximity Sensors PDF catalog.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state off the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E2B-S08LN04-MC-C2 PDF datasheet.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E2B-S08LN04-MC-C2 PDF catalog.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.