Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms D4N-8122 PDF catalog.
(Slow-action models with MBB contacts are available
D4N-8122)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC D4N-8122 PDF catalog. Supports ISO 13849-1 (PLe/Safety Category 4).
Can be used on higher risk level applications,
by connecting to Safety Controllers.
Supports a wide range of applications in combination with,
Safety Controller G9SP or Non-contact Door Switch,
Controller G9SX-NS@.
Up to 30 units can be connected.
Ideal for middle to large scale device applications.
Contributes to shortening the time it takes to find,
the cause of failure by the switch''s LED display patterns D4N-8122 PDF catalog.
Photocoupler monitor output allows connection to,
a general-purpose PLC (NPN type).
Compatibility with the D40A allows standardization of machine design.
Compact Non-contact Door Switch can be mounted from both sides OMRON Safety Limit Switch PDF catalog. Actuator: Roller lever (resin lever, resin roller).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC/1NO (Slow-action) OMRON Safety Limit Switch PDF catalog.
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement OMRON Safety Limit Switch PDF catalog.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Actuator: Roller plunger.
Conduit openings: G1/2 (PF1/2).
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion D4N-8122 PDF datasheet.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4N-8122 PDF catalog.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.