Product model: D4N-1A26
Name: Safety Limit Switch
Brand: OMRON
Sort: PDF datasheet
File language: English
Actuator: Shaft.
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 1NC/1NO MBB (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms D4N-1A26 PDF datasheet.
1NC/1NO, and 2NC. Models with MBB contacts are also available D4N-1A26
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads. Actuator: Roller lever (resin lever, metal roller).
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards D4N-1A26 PDF datasheet.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4N-1A26 PDF datasheet.
Certified standards: UL, EN (TÜV), and CCC. High Reliability for Micro Load,
Applications, Even in Adverse,
Atmospheres (Dust, High Humidity, Silicon Gas, etc.)
The reed switch offers exceptional contact.
reliability in micro load applications.
Same mounting pitch as for the V Miniature Basic Switch.
High durability with a bounce time of 1 ms max. Lock method: Solenoid lock.
Conduit size: M20.
Voltage for solenoid: 24 VDC.
With LED indicator 2NC+ 1NC (Slow-action).
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporating a switch box with,

degree of protection satisfying IP67, UL, and CSA TYPE6P, 13 D4N-1A26 PDF catalog.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key ffor a swinging door are available D4N-1A26 PDF catalog.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions.
Related products
OMRON
Safety Limit Switch
D4N-2C25
OMRON Safety Limit Switch D4N-2C25
Actuator: Roller lever metal lever, met
OMRON
Safety Limit Switch
D4N-2C62
OMRON Safety Limit Switch D4N-2C62
Actuator: One-way roller arm lever hori
OMRON
Pull-reset Safety Limit Switch
D4N-4C31R
OMRON Pull-reset Safety Limit Switch D4N-4C31R
Actuator: Plunger. Conduit size: 1-cond
OMRON
Safety Limit Switch
D4N-1120
OMRON Safety Limit Switch D4N-1120
Actuator: Roller lever resin lever, res