C500-OD I/O Unit Transistor Output 16 pts C500-OD219.
DC12-24V 2.1A.Product name: N@@S1- type CPU Units with 40 I/O Points.
Specifications: Power Supply, DC24V; Inputs, 24; Outputs, 16;
Output type: Transistor (sourcing).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): -- CS1W-OD291 PDF datasheet.
Current consumption: 5 V, 0.31A; 24 V,0.02A.
Standards: CE
CS1W-OD291
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection CS1W-OD291 PDF datasheet. CPU Unit: CP1L-L CPU Units with 10 Point.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Transistor output (sinking);
Inputs, 6; Output, 4.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet CS1W-OD291 PDF datasheet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. I/O points: 256 pts.
Program capacity(words): 3.2 K.
DM capacity (words): 3 K.
RS-232C port: YES.Used to attach Hand-held Programming Console to a panel.Name: Analog I/O Slave Units,
(Numerical indicator type)
e-CON Connector Type.
Specifications: Analog outputs; 2 outputs.
Standards: CE.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the locationn and,
content of the error CS1W-OD291 PDF catalog. UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 1, 184 points.
Max. no.of con-necting Expansion I/OO Racks: 3 Racks CS1W-OD291 PDF catalog.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.