LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Catalog Download >> CRT1-ID08TA-1
OMRON CRT1-ID08TA-1 PDF catalog CRT1-ID08TA-1 datasheet PDF datasheet
Product model: CRT1-ID08TA-1
Name: CompoNet Gateway Unit for CC-Link
Brand: OMRON
Sort: PDF datasheet
File language: English
UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 1, 184 points.
Max. no.of con-necting Expansion I/O Racks: 3 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10 CRT1-ID08TA-1 PDF datasheet.
RS-232C: NO.Power supply: DC power supply CRT1-ID08TA-1
Output method: Transistor output source type.
Inputs points: 12 points.
Outputs points: 8 points.Unit type: CS1 Special analog I/O Units.
Product name: Analog Output Units.
Specifications: I/O points, 8 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point CRT1-ID08TA-1 PDF datasheet.
Externa connection, Removable erminal block.
Current consumption: 5V, 0.13A; 26V, 0.18A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals.Model: C500-BC051.
5 slots(3 linkable slots) CRT1-ID08TA-1 PDF datasheet.
Product name: N@@S1- type CPU Units with 60 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 36; Outputs, 24;
Output type: Relay.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0.21A; 24 V,0.13A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. 4 platinum resistance thermometer inputsUnit type: CJ1 Basic I/O Units.
Product name: DC Input Units.
Specifications: I/O points, 32 inputs(High speed);
Input voltage and current: 24 VDC, 4.1 mA;
Commons, 16 points, 1 common; External connection,
MIL connector; No. of words allocated, 2 word.
Current consumptioon: 5V, 0 CRT1-ID08TA-1 PDF catalog. 20A; 24V, --.
Standards: N, L, CE.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memoory in the CPU Unit CRT1-ID08TA-1 PDF catalog.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput.
Related products
OMRON
CompoNet Gateway Unit for CC-Link
CRT1-ID16-1
OMRON CompoNet Gateway Unit for CC-Link CRT1-ID16-1
Name: Two-tier Screw Terminal Block. Sp
OMRON
CompoNet Gateway Unit for CC-Link
CRT1-ID08SL-1
OMRON CompoNet Gateway Unit for CC-Link CRT1-ID08SL-1
Name: Clamp Terminal Blocks. Specificat
OMRON
CompoNet Gateway Unit for CC-Link
CRT1-ID08TAH-1
OMRON CompoNet Gateway Unit for CC-Link CRT1-ID08TAH-1
Name: Three-tier Screw Terminal Block.
OMRON
CompoNet Gateway Unit for CC-Link
CRT1-ID16
OMRON CompoNet Gateway Unit for CC-Link CRT1-ID16
Name: Two-tier Screw Terminal Block. Sp