Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function E3Z-L86 PDF datasheet .
Event entry point: 2.
Transfer output: -
E3Z-L86
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C E3Z-L86 PDF datasheet .
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E3Z-L86 PDF datasheet .
Through the infrared port can be carried out from the front of the communication OMRON E3Z-L86 PDF catalog.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Classification: Exclusive Models OMRON E3Z-L86 PDF catalog.
Description: Used for room temperature measurement.
Temperature range (See note 3.): -50°C to 60°C .
Element type: Pt100.
Conductor type: 3-conductor system.
Class: B.
Protective tubing material: SUS304.
Terminal type: Exposed lead wires.
Page: 40.
A Wide Variety of High-precision OMRON E3Z-L86 PDF catalog.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensorrs according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E3Z-L86 datasheet. Size: M8(Stainless steel)(See note 2.); Double; Unshielded.
Sensing distance: 4 mm.
Connnecting method (See note 1 E3Z-L86 PDF datasheet . ): Pre-wired.
Body length: Short.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications.