MITSUBISHI R62P datasheet PDF datasheet
Product model: R62P
Name: Power module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
"Input points: 16 points.
Rated input voltage and frequency: DC24V.
Rated input current: TYP 7.0mA.
Response time: 0.1 ~ 70ms.
Common way: 16 point / public end.
Interrupt function: have.
External wiring connection mode: 18 point screw terminal.
The input and output module is the interface between the switch, sensor, actuator, and other control system of the ON/OFF signal processing R62P datasheet R62P
Compared with the previous series, iQ-R MELSEC series of input and output modules have more features,
1 modules can be used for a variety of purposes, to help reduce the cost of deployment and maintenance costs.
The module design of the pursuit of convenience".
Paste the white label on the input module and paste the red label on the output module,
The rated specifications are clearly marked on the front of the module, which can prevent the use of errors R62P datasheet.
The input and output number stamped on the top of the front display input and output module LED, can easily confirm the status of the ON/OFF.
The terminal arrangement of each signal is recorded on the wiring terminal of the 16 point module, and the false wiring can be prevented R62P datasheet.
The 64 point module can be 32 points as the unit, through the switch to switch to display the input and output number.
In addition, serial number tag in the front of the module, can be easily recognized. "10Mbps Max., master / local station, support Ver.2 CC-Link.
CC-Link is a bus (RS-485) - type open field network which can control and information processing at the same time.
Can be in the CC-Link and high-speed transmission of ON/OFF information from the station equipment, such as bit data, analog information, such as digital data.
Connect all kinds of field equipment through CC-Link.
Can connect all kinds of support CC-Link field equipment, according to various control requirements to build the corresponding system.
Use remote device network mode, up to 64 remote equipment such as analog devices, etc.. Output points: 32 points.
Output form: Transistor (drain type) output.
Rated open and close voltage, current: -.
Rated load voltage: DC12 ~ 24V.
Max load current: 0.2A/ point.
Response time: 1ms.
Common way: 32 point / public end.
Protection function (overload, overheat).
External wiring connection mode: 40 pin connector.
Output module with mechanical relay contact mechanism,
Including the load voltage range of the relay and can be used for the output of the DC12~24V load transistor output type R62P PDF datasheet.
According to the load voltage, the output points of different, choose the most suitable user needs of the module.
Preventive maintenance based on the life of relay contact.
Relay output module can accumulate the number of OON of each output point R62P PDF datasheet.
Through the understanding of the relay contacts of the number of times, according to the relay life of preventive maintenance.
Related products
MITSUBISHI
Transistor output module (drain type)
QY42P
MITSUBISHI Transistor output module (drain type) QY42P
Output points: 64 points. Output voltage
MITSUBISHI
Analog output module
R60DA4
MITSUBISHI Analog output module R60DA4
Analog output channel numer: 4CH. accur
MITSUBISHI
External connection cable
GT16H-C50-32P
MITSUBISHI External connection cable GT16H-C50-32P
Cale length: 5m. The connection etween
MITSUBISHI
Power module
R63P
MITSUBISHI Power module R63P
Input supply voltage: DC24V. Input frequ