Function: input / output module (internal service power supply).
Input / output points: 32 points
Input points: 16 points.
Output points: 16 points.
DC5V internal consumption current: 965mA.
DC24V internal consumption current: 250mA.
Input / output mode: DC input (drain / source) / transistor (drain) FR-HC2-H15K PDF datasheet.
In order to extend the input output of the device.
Also has a built-in power supply products
FR-HC2-H15K
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. Power: 22kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current FR-HC2-H15K PDF datasheet.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose FR-HC2-H15K PDF datasheet. ) MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 7.5kw.
SLD converter rated current: 49A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment).
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps. Analog input points: 4.
Analog output points: 1 points.
Analog input and output expansion module.
With 4CH analog input and 1CH analog output.
With -100mV~100mV micro voltage input range, and thereefore do not need a signal converter, etc FR-HC2-H15K PDF catalog. .
Resolution of 15 bit binary + symbol 14bit, 1bit binary + symbol 1bit high precision analog input and output modules.
Each channel can be used for different input ranges.
Built in iinput filter adjustment function, internal operation function, proportion function FR-HC2-H15K PDF catalog.
Connect FX3UC, FX3GC, you need to use FX2NC-CNV-IF or FX3UC-1PS-5V.