LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Catalog Download >> FR-A7ND
MITSUBISHI FR-A7ND datasheet PDF datasheet
Product model: FR-A7ND
Name: Net Device communication module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Max input / output points: 48 points.
Power supply voltage: 24VDC.
Input points: 24 points.
Output points: 24 points.
Output type: transistor.
Power consumption: 30W.
Weight (kg):0.85.
Size (WxHxD) mm:182x90x87 FR-A7ND datasheet.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard FR-A7ND
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register FR-A7ND datasheet.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications FR-A7ND datasheet.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable. Input / output type: DC input (drain / source).
Input and output points: 8 points.
DC5V internal consumption current: 75mA.
DC24V internal consumption current: 50mA.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. "MITSUBISHI inverter FR-F720P series.
Voltage level: three phase 200V.
Frequency converter capacity: 90KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes.
For the requirements of relatively high precision, even if the load changes are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection).
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is maainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FR-A7ND PDF datasheet.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FR-A7ND PDF datasheet. "
Related products
MITSUBISHI
3 phase 400V converter
FR-F740-5.5K-CHT
MITSUBISHI 3 phase 400V converter FR-F740-5.5K-CHT
"MITSUBISHI inverter FR-F740 series. Vol
MITSUBISHI
PLG cable
FR-V7CBL30
MITSUBISHI PLG cable FR-V7CBL30
Length: 30 meters. Cale manufacturing s
MITSUBISHI
3 phase 400V converter
FR-L740-11K-CHT
MITSUBISHI 3 phase 400V converter FR-L740-11K-CHT
MITSUBISHI inverter FR-L740 series. Volt