MITSUBISHI AJ71C24-S6 PDF catalog AJ71C24-S6 datasheet PDF datasheet
Product model: AJ71C24-S6
Name: Computer link module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
3C-2V/5C-2V coaxial cable.
Double loop.
Remote station.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system AJ71C24-S6 PDF datasheet AJ71C24-S6
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc AJ71C24-S6 PDF datasheet. . Input points: 32 points.
Voltage: AC100 ~ 120V.
Current: 10mA.
Response time: 35ms.
16 points / a common end.
36 point terminal station.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read AJ71C24-S6 PDF datasheet.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requiirements,
Should consider the best performance to price ratio, a reasonable choice of PLC AJ71C24-S6 PDF catalog.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation AJ71C24-S6 PDF catalog.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
Related products
MITSUBISHI
Upper controller connection module
AJ71C22S1
MITSUBISHI Upper controller connection module AJ71C22S1
RS-422 1 channel. Transfer speed: 38.4k
MITSUBISHI
Computer link module
AJ71C24-S3
MITSUBISHI Computer link module AJ71C24-S3
RS-232:1, RS-422/485:1. Transmission spe
MITSUBISHI
Terminal interface module
AJ71C21-S1
MITSUBISHI Terminal interface module AJ71C21-S1
RS-232:1 channel, RS-422:1 channel. BASI
MITSUBISHI
Computer link module
AJ71C24-S5
MITSUBISHI Computer link module AJ71C24-S5
RS-232:1, RS-422/485:1. Transmission spe