MITSUBISHI A6CON2E PDF catalog A6CON2E datasheet PDF datasheet
Product model: A6CON2E
Name: Connector
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
2 channel analog output module.
As well as analog input modules, the A1S62DA analog output component is built into a microprocessor,
It can convert binary data into voltage or current signals,
Offset and gain are set and stored in a microprocessor,
It also includes other features as follows:
2 output channels A6CON2E PDF datasheet.
High resolution digital input, plus or minus 12000.
Total accuracy plus or minus 1% A6CON2E Cable length: 3 meters.
For QnA/A/FX (FX1, FX2, FX2C) CPU and GOT connection between.
For connection between FA-CNV_CBL and GOT.
For connection between FX-2PIF and GOT.
For connection between FX-422AW0 and GOT.
For serial communication module AJ71QC24 (N) -R4 and GOT connection between.
For connection between AJ65BT-G4-S3 and GOT A6CON2E PDF datasheet. Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5mA.
External connection: 1 wire.
Type of input and output terminal.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module A6CON2E PDF datasheet. Input points: 32 points.
Input voltage: AC200 ~ 240V.
Current: 5mA.
Response time: 55ms.
16 points / a common end.
50 point terminal station.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the compoonent image register are changed with the change of the execution of the program A6CON2E PDF catalog.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to thhe adoption of centralized sampling A6CON2E PDF catalog.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
Related products
MITSUBISHI
On line connector for power supply
A6CON-PW5JP
MITSUBISHI On line connector for power supply A6CON-PW5JP
A pack of 5. Applicale models: AJ65VBTS
MITSUBISHI
Quick connector plug
A6CON-P214
MITSUBISHI Quick connector plug A6CON-P214
A pack of 20. Applicale models: AJ65SBT
MITSUBISHI
Connector
A6CON2
MITSUBISHI Connector A6CON2
32 point connector for compression conne