Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage OMRON Three-phase Undervoltage and Phase-sequence Phase-loss Relay PDF datasheet.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K8DS-PU1
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON Three-phase Undervoltage and Phase-sequence Phase-loss Relay PDF datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Appearance: square shell embedded F1.
Static type reverse electric relay K2WR type.
Reverse power relay for household and marine generator.
A high precision power detection can be performed by the analog time division multiplier OMRON Three-phase Undervoltage and Phase-sequence Phase-loss Relay PDF datasheet.
Through the rated voltage of the switch, adjust the current simulation of variable,
Can correspond to the rated value of all generators K8DS-PU1 PDF datasheet.
Due to the instant start in contact, the response difference is minimal,
Position detection with high accuracy K8DS-PU1 PDF datasheet. Sharing with voltage input, no need to control the power supply.
Because it is static, so the anti vibration impact ability, action stability.
Equipped with easy to manage and maintain the boot display with LED. Type of input: AC current input K8DS-PU1 PDF datasheet.
Output type: BCD+ transistor; -; NPN open collector (5 bit output +HH, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulatioon, measurement and display, identification of the panel table K8DS-PU1 PDF catalog.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the suub pressure gauge for monitoring the operation trend OMRON Three-phase Undervoltage and Phase-sequence Phase-loss Relay PDF datasheet.
External event input can be applied to a variety of measurement and identification situations.
D