LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Catalog Download >> K8AK-AS2 24VAC/DC
K8AK-AS2 24VAC/DC PDF catalog OMRON K8AK-AS2 24VAC/DC datasheet PDF datasheet
Product model: K8AK-AS2 24VAC/DC
Name: Single-phase Current Relay
Brand: OMRON
Sort: PDF datasheet
File language: English
Time specification: Instantaneous type.
Current setting range: 2 to 8 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage OMRON K8AK-AS2 24VAC/DC PDF datasheet.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K8AK-AS2 24VAC/DC
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON K8AK-AS2 24VAC/DC PDF datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Open circuit mode: current circuit breaker.
Appearance: ADR shell.
Rated current: AC110V.
Rated frequency: 50/60Hz.
Consume VA: action time 10VA below (except for reactor part) OMRON K8AK-AS2 24VAC/DC PDF datasheet.
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: 1A; closed circuit 110V 15A DC 1000 (L/R=0ms),
Open 110V 1A DC 1000 (L/R=25ms).
The relay control output circuit breaker switch: power capacity, switching capacity, AC110V/10A C110V/10A; (COS =1).
Quality: about 1kg.
External: Mount Searl N1.5.
High voltage grounding relay type K2GA thin,
Miniaturization, and digital type precision mounting.
Strong anti interference ability,
Stable operation in the arc grounding fault.
Can carry out fine current adjustment, easy to coordinate.
Set alarm terminal.
The adjusting part of the action current is a rotary switch mode, which is convenient for adjustment. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control,, and cyclic control K8AK-AS2 24VAC/DC PDF catalog.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K8AK-AS2 24VAC/DC PDF catalog.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).