Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage OMRON Digital Heater Element Burnout Detector PDF datasheet.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K8AC-H22CN-FLK
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON Digital Heater Element Burnout Detector PDF datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Power supply voltage: 24 VAC/DC.
Ideal for Liquid Level Control in.
Industrial Facilities and Equipment.
Self-holding circuit implemented with circuit processing that is,
not depending on external wiring OMRON Digital Heater Element Burnout Detector PDF datasheet.
Switch between water supply and discharge with a DIP switch setting.
Sensitivity adjustment of operating resistance from 10 k to 100,
kΩ for application to a wide range of liquids K8AC-H22CN-FLK PDF datasheet.
Prevents chattering of relay contacts that occurs with ripples K8AC-H22CN-FLK PDF datasheet.
Easy wiring with ferrules.
Use 2 × 2.5 mm2 solid wire or 2 × 1.5 mm2 ferrules.
Applicable as a floatless switch. Setting range: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment K8AC-H22CN-FLK PDF datasheet.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and undervoltages.
Manual resetting and automaticallly resetting supported by one Relay K8AC-H22CN-FLK PDF catalog.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input ssupported OMRON Digital Heater Element Burnout Detector PDF datasheet.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.